Urban Wildfire Defense Cart Operating Instructions
Please Contact Us for the full Users Manual
Step 1
Get Ready --
Move the Urban Wildfire Defense Cart into position
-- near the water source
-- maintaining safe distance
Attach Ingress Suction hose to the pump.
Drop the other end of the Ingress Suction hose into the water.
Assure the Gas Can is filled
Realize Safety recommends using Ethanol-Fee Fuel such as TruFuel
Step 2
Prime the Pump --
- Open the port.
- Fill with 1 gallon of water.
- Close and tighten to seal.
Pump requires one initial priming
Step 3
Connect Fire Hoses
Attach the Egress Fire Hose to the pump.
Attach the end of the Fire Hose
- to a Spray Nozzle or
- to an Exposure Defender.
Step 4
Operate the System
Turn the run switch to the On position
Adjust the Choke to On
Adjust the Fuel Switch to Full On
Pull the cord
Adjust Fuel switch to desired operating speed
Step 5
After system operation
Disconnect Ingress Suction hose
Disconnect Egress Fire Hoses
Drain the system of water by opening the impeller drain plug