Urban Wildfire Defense Cart Operating Instructions

Please Contact Us for the full Users Manual

Step 1

Get Ready --

Move the Urban Wildfire Defense Cart into position

-- near the water source

-- maintaining safe distance

Attach Ingress Suction hose to the pump.

Drop the other end of the Ingress Suction hose into the water.

Assure the Gas Can is filled

Realize Safety recommends using Ethanol-Fee Fuel such as TruFuel

Step 2

Prime the Pump --

  • Open the port.
  • Fill with 1 gallon of water.
  • Close and tighten to seal.

Pump requires one initial priming

Step 3

Connect Fire Hoses

Attach the Egress Fire Hose to the pump.

Attach the end of the Fire Hose

  1. to a Spray Nozzle or
  2. to an Exposure Defender.

Step 4

Operate the System

Turn the run switch to the On position

Adjust the Choke to On

Adjust the Fuel Switch to Full On

Pull the cord

Adjust Fuel switch to desired operating speed

Step 5

After system operation

Disconnect Ingress Suction hose

Disconnect Egress Fire Hoses

Drain the system of water by opening the impeller drain plug